Gasboy Atlas Technician Programming Quick Ref Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Gasboy Atlas Technician Programming Quick Ref. Gasboy Atlas Technician Programming Quick Ref User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 2
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Command Code 7:
Program Totals Input
Press Enter after making selections.
• Enter 7
• Select Side
1 : Side A
2 : Side B
• Select Grade
• Press $ Total
• Enter Money Total
(Repeat for other Side and Grade)
• Press Volume Total
(Repeat above procedure for Volume
Totals )
Command Code 8:
Display Version Number
Press Enter after making selections.
• Enter 8
• Select Software Option
1 : Pump Controller
* Default to system software, if
pump/dispenser is not a Blender.
**1 : Side A
2 : Side B
3 : Both Sides
From Level 2
Command Code 10:
System Configuration
Press Enter after making selections.
• Enter 10.
• Enter Function #.
• Enter Configuration #.
Function Code 2:
Money Decimal Point
1 = xxxxx
2 = xxxx.x
3 = xxx.xx***
4 = xxx.xxx
Function Code 3:
Calculation PPU Decimal Point
(Required in U.S. per Weights and
Measures)
1 = xxxx
2 = xxx.x
3 = xx.xx
4 = x.xxx***
Function Code 4:
Displayed PPU Decimal Point
Self configures default value.
1 = xxxx
2 = xxx.x
3 = xx.xx
4 = x.xxx
Function Code 5:
STP Prestart
0 = Off***
1=On
Function Code 6:
Beeper Option
0=Off
1 = On***
Function Code 8:
Two-Wire Display Blank Option
0 = Off***
1=On
Function Code 9:
5 or 6-digit Cash Display
0 = 5-Digit Money***
1 = 6-Digit Money
Function Code 10:
Decimal/Comma Mode
0 = Comma Off***
1=Comma On
Function Code 11:
Preselect Time-Out
0 = None
1 = 5 seconds
2 = 15 seconds***
3 = 30 seconds
4 = 45 seconds
5 = 60 seconds
6 = 75 seconds
7 = 90 seconds
8 = 120 seconds
Function Code 14:
G6 Push to Start
0 = Off***
1=On
Function Code 15:
Zero PPU Pricing Option Enable
0 = Disabled***
1=Enabled
Function Code 16:
Beeper Time-out
0 = Off***
1 = 5 seconds
2 = 15 seconds
3 = 30 seconds
4 = 45 seconds
5 = 60 seconds
6 = 75 seconds
7 = 90 seconds
8 = 120 seconds
9 = 240 seconds
Function Code 17:
Push to Stop Control
0 = Stop controls one side***
1 = Stop controls two sides
Function Code 18:
Zero Previous Transaction After
Pump Handle Operation
0 = Zero after lamp test***
1 = Zero before lamp test†
Function Code 20:
Programmable Pump Preset Value
0 = Value x 1 (enter fractions)
1 = Value x 10 (enter whole units)
MDE-4404A
Atlas
Technician Programming
Quick Reference Card
July 2010
From Level 1
Command Code 1:
Program PPU
Press Enter after making selections.
• Enter 1
• Select Side**
• Select Grade
• Select Price Level
• Enter new PPU
(Repeat for other Side, Grade, and
Price Level)
Command Code 2:
Program Two-Wire/Standalone
Press Enter after making selections.
• Enter 2
• Select Configuration
0 : Standalone
1 : Two-Wire*
2 : Pulse Output
Command Code 3:
Program Allocation
Press Enter after making selections.
• Enter 3
• Select Side**
• Select Hose/Grade
• Enter Allocation amount
(000.0 default)
(Repeat for other Side, Hose, and
Grade)
Command Code 4:
Program Manual Blank Display
Cash/Volume Preset Select
Press Enter after making selections.
• Enter 4
Select Function Code 1
Function Code 1:
Manual Blank Displays
0 : Display OFF
1 : Display ON*
Command Code 5:
Test/Program
Customer Programmable Preset
Press Enter after making selections.
• Enter 5
• Select Configuration
0 : STOP Test/Program
1 : START Test/Program
(After the test is complete, refer to the
programming steps in MDE-2531
Pump/Dispenser Service Manual.)
Command Code 6:
Memory Clear for Error Code 31
or 35
Press Enter after making selections.
• Enter 6
• Select 1
Software Versions
For details on software versions, refer to MDE-4331 Atlas
Fuel Systems
Installation Manual, MDE-4334 Atlas Startup and Service Manual, and MDE-4363
Atlas Fuel Systems Owner’s Manual.
Power-up and Command Code 8 display the current software version.
Display Pump Totals
• Press Enter after making selections.
• Press $ Total
• Select Grade
• Press Volume Total
• Select Grade
• Press Enter to view Side 2 totals
• Press Clear to exit
PIN Code Entry
Level 1 - Press F1, type 4-digit ID (default 2222), and press Enter.
Level 2 - From Level 1, type any Level 2 Command Code (10-12), type 4-digit ID
(default 1503), and press Enter.
Level 3 - From Level 2, type any Level 3 Command Code (13-17), type 4-digit ID
(default 1309), and press Enter.
Press F1 to exit any command code.
Press F2 to return to normal operation
Przeglądanie stron 0
1 2

Podsumowanie treści

Strona 1 - PIN Code Entry

Command Code 7: Program Totals InputPress Enter after making selections.• Enter 7 • Select Side1 : Side A2 : Side B • Select Grade• Press $ To

Strona 2 - Error Codes

Call Gasboy Technical Support at: 1-800-444-5529©2010 Gasboy International · 7300 W. Friendly Avenue · Post Office Box 22087 Greensboro, NC 27420 · P