MDE-4298D CFN Series Site Controller III Installation Manual · September 2009 Page 77
Installation Completion Checklist Testing
6 – Testing
Installation Completion Checklist
The information below should be reviewed to help verify proper installation of the CFN
system prior to testing pumps and/or remote dispensers in the manual override position.
Are the CFN system components located in the proper environment as described in
“Purpose” on page 9?
Is there adequate clearance around the ICRs (refer to “Purpose” on page 9, “ICR” on
page 14, and “ICR2 (PA0398X0XXX0)” on page 18)?
Is all the wiring inside the metal conduit, except as noted in “Short Haul Modem (SHM)
RS-422” on page 39?
Is the AC and DC wiring in separate conduits, troughs, and so on? If they are not, and if
the AC and DC wires share the conduit, a shielded cable must be used as specified in
“Communication Requirements” on page 33, “RS-485” on page 33, “Short Haul Modem
(SHM) RS-422” on page 39, or “Pulser Wiring and Configuration” on page 53.
Are the CFN system components on a separate dedicated breaker (refer to “System
Components Wiring” on page 31)
Are pumps over 3/4 HP at 120/240 VAC or 1-1/2 HP at 240 VAC equipped with a starter
relay (refer to “Pump/Remote Dispenser Wiring” on page 43)?
Is the correct gauge wire installed for the following:
- System (refer to “System Components Wiring” on page 31)?
- Pumps (refer to “Pump/Remote Dispenser Wiring” on page 43)?
- Remote dispensers (refer to “Pump/Remote Dispenser Wiring” on page 43)?
- Pulsers (refer to “Pump/Remote Dispenser Wiring” on page 43)?
- SHMs (refer to “System Components Wiring” on page 31)?
Are the communication lines under the maximum allowable distance for the following:
- RS-232 - 100 feet (refer to “System Components Wiring” on page 31)?
- RS-485 - 1000/1500 feet (refer to “System Components Wiring” on page 31)?
- RS-422 (SHMs) - 1500 feet (refer to “System Components Wiring”
on page 31)?
If the system has an external modem, is the phone line installed (refer to “System
Components Wiring” on page 31)?
Is there fuel in the tanks?